Central Feed System - H.E. Anderson Pump Calibration

In this video learn how to calibrate H.E. Anderson Pumps on the Growlink Central Feed System

Pump calibration requires using a calibration column tool. If you do not have a calibration column, please contact us at 1 (800) 432-0160 or support@growlink.com to submit a purchase request.

Use this table of target injection rates for the 4 main injector pump models used. Find the model and current dial position to determine the total injection volume you're looking to hit. Follow the steps in the video to complete a proper calibration.

 

Dial Position

Pump Model

10

9

8

7

6

5

4

3

2

1

H4

400 ml

360 ml

320 ml

280 ml

240 ml

200 ml

160 ml

120 ml

80 ml

40 ml

P2

200 ml

180 ml

160 ml

140 ml

120 ml

100 ml

80 ml

60 ml

40 ml

20 ml

P1

100 ml

90 ml

80 ml

70 ml

60 ml

50 ml

40 ml

30 ml

20 ml

10 ml

A3

30 ml

27 ml

24 ml

21 ml

18 ml

15 ml

12 ml

9 ml

6 ml

3 ml